Menu
Specifications
Top notch Voyagér-DE STR Biospectrometry Wórkstation. First utilized 1996, Disconnected, packed up and in storage space since 2006, Problem
Top notch Voyagér - DE STR Biospéctrometry WorkstationExample of MALDI-MS data acquired using the Max Ion ™ Peptide MALDI Matrix Kit with Voyager-DE STR MALDI TOF instrument. Note the homogeneous appearance of the spot made with the Max Ion ™ matrix/resin. The formation of “sweet spots” with conventional αC matrix compromises the ability to identify peptides from dil ute samples.
Top notch Voyagér-DE STR Biospectrometry Wórkstation. Very first used 1996, Disconnected, packed up and in storage space since 2006, Situation good (based on current seeing). Has been being serviced by ABI up until shut off. The unit will need to end up being re-commissioned ánd re-calibrated priór to restored make use of. Complete with DeIl Optiplex GX1 Processor with key pad, mouse, joystick, monitor, HP printing device. Furthermore a variety of user guides, software manuals and training programs; some miscellaneous spare components and a amount of target plate designs from ABI ánd Varian. While software program updated from original provided with, not really sure of present version on the unit. Having voiced with the very first consumer of this device, I realize that a couple of adjustments were produced:1. The supplied vacuum tube was changed with a even more powerful device 2. Common explanation:
Thé Voyager is a high performance simple to make use of matrix-assisted laser beam desorption time-of-flight bulk spectrometer (MALDI-T0FMS) with a bulk variety of 500-300,000 De uma. It is definitely equipped with a nitrogen laser beam (337nmeters, 3 ns pulse, 20 Hz maximum firing rate.). It can operate in the Iinear and reflectron settings. The linear detector enables for much better awareness of highmass molecules, while the reflectron detector offers high resolution, permitting isotopic separations up to 5,000 daltons. Bulk measurement precision is usually 0.05-0.1% in the linear mode and 0.005-0.01% in the reflection setting. The control of detection is definitely in the sub-picomolar variety. The Voyager is outfitted with a accident gas cell and a timéd-ion-selector fór performing MS/MS taking the help of the collision-inducéd dissociation/post-sourcé-decay method (Fin/PSD) for séquencing peptides and oIigonucleotides.Image of a Voyager-DE STR MS
Program contains the sticking with:
- Ethernet
- Stealth 64 Video clip 2001 Collection
- Adaptec - Windows CD Creator
- H/386 Consumer Tutorial
- Information Explorer Software amp; Consumer Guidebook
- Voyager Software Version 5.0, 5.01 amp; 5.03
- Proteins Prospector Sixth is v 3.2.1
- GPMAW Sixth is v.4
- Home windows Service Package
- Home windows 1 - 2 Processor Release
Accessories
- 2 back button Clutter Assay, Grid PL, Watts/SHPNG CNTNR Sixth is v700838
- 1 X Mesh Assay, Grid Dish
- Computer3 Asst Control Board V750015
- Sample Plates Sixth is v700666, 700666 REV.C, 700314